Delfield, Specifications – Delfield F18BC User Manual

Page 4

Advertising
background image

F18 Series Service and Installation Manual

For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com

4

Delfield

®

Specifications

MODEL

# OF

SHELF AREA

# OF

RECOMMENDED

VOLTS/HERTZ/

BTU DESIGN

EVAP. CAP.

NUMBER

DOORS

SQ. FT.

PANS

HORSE POWER

PHASE

AMPS

BASE/RAIL

BTU/°TD

Remote Refrigerated Salad Top Tables
F18SR31A

(1) 19”

2.56

6

1/4

115/60/1

3.0

280/265

120

F18SR44A

(2) 19”

5.12

6

1/4

115/60/1

3.0

491/441

120

F18SR44B

(2) 19”

5.12

8

1/4

115/60/1

3.0

491/441

120

F18SR44C

(2) 19”

5.12

10

1/4

115/60/1

3.0

491/441

120

F18SR52A

(1) 19” & (1) 27”

6.51

6

1/4

115/60/1

3.0

532/529

120

F18SR52B

(1) 19” & (1) 27”

6.51

8

1/4

115/60/1

3.0

532/529

120

F18SR52C

(1) 19” & (1) 27”

6.51

10

1/4

115/60/1

3.0

532/529

120

F18SR52D

(1) 19” & (1) 27”

6.51

12

1/4

115/60/1

3.0

532/529

120

MODEL

# OF

SHELF AREA

# OF

VOLTS/HERTZ/

BTU DESIGN

BTU SYSTEM CAP.

NUMBER

DOORS

SQ. FT.

PANS

HORSE POWER

PHASE

AMPS

BASE/RAIL

BASE/RAIL

Self-Contained Refrigerated Salad Top Tables
F18SC39A

(1) 19”

2.56

6

1/4

115/60/1

10.0

280/265

1903/745

F18SC39B

(1) 19”

2.56

8

1/4

115/60/1

10.0

280/353

1903/867

F18SC52A

(2) 19”

5.12

6

1/4

115/60/1

10.0

444/265

1903/745

F18SC52B

(2) 19”

5.12

8

1/4

115/60/1

10.0

444/353

1903/867

F18SC52C

(2) 19”

5.12

10

1/4

115/60/1

10.0

444/441

1903/971

F18SC52D

(2) 19”

5.12

12

1/4

115/60/1

10.0

444/529

1903/1061

F18SC60A

(2) 19” & (1) 27”

6.51

6

1/4

115/60/1

10.0

515/265

2314/667

F18SC60B

(2) 19” & (1) 27”

6.51

8

1/4

115/60/1

10.0

515/353

2314/798

F18SC60C

(2) 19” & (1) 27”

6.51

10

1/4

115/60/1

10.0

515/441

2314/916

F18SC60D

(2) 19” & (1) 27”

6.51

12

1/4

115/60/1

10.0

515/529

2314/1023

A 5-15P NEMA plug is used on self-contained units

MODEL

# OF

STORAGE

SHELF AREA

# OF

RECOMMENDED

VOLTS/HERTZ/

BTU DESIGN LOAD

EVAP. CAP.

NUMBER

DOORS

CU. FT.

SQ. FT.

PANS

HORSE POWER

PHASE

AMPS

BASE/RAIL

BTU/°TD

Remote Refrigerated Reduced Height Rail
F18DR44

(2) 19”

9.49

5.12

10

1/4

115/60/1

3.0

547/441

120/19

F18DR52

(1) 19” & (1) 27”

11.81

6.51

12

1/3

115/60/1

3.0

625/529

120/23

F18DR60

(2) 27”

14.14

7.9

16

1/3

115/60/1

5.0

703/617

120/26

F18DR70

(2) 32”

17.05

9.64

18

1/2

115/60/1

5.0

800/794

120/32

F18DR79

(1) 19” & (2) 27”

18.68

10.29

18

1/2

115/60/1

5.0

962/882

240/36

F18DR87

(3) 27”

21.30

11.85

22

3/4

115/60/1

5.0

1032/970

240/39

MODEL

# OF

STORAGE

SHELF AREA

# OF

VOLTS/HERTZ/

BTU LOAD

BTU SYSTEM CAP.

NUMBER

DOORS

CU. FT.

SQ. FT.

PANS

HORSE POWER

PHASE

AMPS

BASE/RAIL

BASE/RAIL

Self-Contained Refrigerated Reduced Height Rail
F18DC52

(2) 19”

9.49

5.12

12

1/4

115/60/1

10.0

547/529

1903/1061

F18DC60

(1) 19” & (1) 27”

11.81

6.51

14

1/3

115/60/1

12.0

625/617

2314/1121

F18DC68

(2) 27”

14.14

7.9

18

1/3

115/60/1

12.0

703/794

2314/1544

F18DC82

(2) 32”

17.05

9.64

20

1/2

115/60/1

14.0

800/882

3097/1648

F18DC91

(1) 19” & (2) 27”

18.68

10.29

22

1/2

115/60/1

14.0

962/1058

3807/1839

F18DC99

(3) 27”

21.30

11.85

24

3/4

115/60/1

16.0

1032/1147

5286/2191

A 5-15P NEMA plug is used on F18RC52, F18RC60 & F18RC68 . A 5-20P NEMA plug is used on , F18RC82, F18RC91, & F18RC99.

Advertising