Introduction, Key features, Chassis model overview – FiberPlex RMC-3101 User Manual

Page 4

Advertising
background image

Introduction 

The FiberPlex Technologies RMC‐2101 / RMC‐3101 / RMC‐3102 chassis are standard 19” rack mountable 
chassis.  Each chassis provides up to nine (9) available slots for any FiberPlex fiber optic isolator (FOI) or 
telephone disconnect unit. Note that the size 3 and TDU units will not fit in the RMC‐2101 chassis. 

The tenth available slot must be occupied by a power supply module. Each chassis will be shipped with one 
power supply module (PSM). A second power supply module may also be added for system power 
redundancy, leaving eight (8) available slots for the installation various combinations of FOI units. If the first 
power supply module fails, the second will assume the entire system load and carry on normally. The failed 
power supply module may be hot swapped with a new one without interruption of FOI operation. 

Each FOI must be mated to a chassis mount adapter (CMA), which interfaces the FOI with the slot and assures 
correct alignment of the isolator power connector and the chassis power bus. 

Key Features 

Up to nine fiber optic isolators may be mounted per chassis. 

Each fiber optic isolator is accessible and removable through the front of the chassis in the RMC‐
3101 and on the rear in the RMC‐2101. 

One PSM‐2010 or ‐3010 power supply and power cord is included with chassis. 

Power redundancy is available through an optional second power supply module. 

A cable bay is provided below the module bay for cable routing on the RMC‐3101 and RMC‐3102. 

Enhanced air flow through two exhaust fans and a vented panel. 

 

Chassis Model Overview 

The following table is a summary of the various chassis models and features. 

 

 

 

Mod

el

 Nu

mb

er

 

RFI

 Sup

p

res

sed

 

Power

 

Rack

 He

ig

ht

 

ST

 Op

ti

cal

 Patch

 

Panel

 

Accommo

d

ate

 

Si

ze

 2

 &

 4

 FO

Mod

els

 

Accommo

d

ate

 

Si

ze

 3

 FOI

 and

 

TDU

 Mo

d

e

ls

 

Power

 S

upp

ly

 

Mod

el

 

(1

 in

cl

ud

ed

Ch

ass

is

 Mo

unt

 

Ad

ap

te

(s

ol

d

 se

pa

ra

te

ly

RMC‐2101 

 

2U 

 

 

PSM‐2010 

CMA‐2001 

RMC‐2101R 

2U 

 

 

PSM‐2010 

CMA‐2001 

RMC‐3101 

 

3U 

 

PSM‐3010 

CMA‐3002 

RMC‐3101R 

3U 

 

PSM‐3010 

CMA‐3002 

RMC‐3102 

 

3U 

PSM‐3010 

CMA‐3002 

RMC‐3102R 

3U 

PSM‐3010 

CMA‐3002 