Model specifications, Top view, Front view – Fire Magic Echelon Diamond Built-In Grill User Manual

Page 7: 7countertop overhang, Non-combustible enclosure cut-out dimensions, Model specifications table

Advertising
background image

7

COUNTERTOP OVERHANG

The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends
beyond the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or
a gap will be created exposing the forward portions of the left and right side grill fi re walls. See illustrations above.

MODEL SPECIFICATIONS

Important:

FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and

cross-ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane

tanks. See the ENCLOSURE REQUIREMENTS section for details.

▲

If equipped

*

Note: If installing this grill in a combustible enclosure, the correct insulating liner must be used. Consult liner instructions for

counter cut-out dimensions and installation.

†

Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See SUBSTRATE

section on next page.

‡

Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section below).

TOP VIEW

Countertop

Lower support

Countertop
overhang

Control panel

NON-COMBUSTIBLE

ENCLOSURE CUT-OUT

DIMENSIONS

Fig. 7-1

FRONT VIEW

B

C

D

Extra cut-out

for Power

Hood only!

1-

1

/

4

" x 10"

11"

See next page

for substrate

considerations

Countertop
overhang

X

TOP VIEW

SIDE VIEW

Countertop

overhang

(Control

panel)

(Countertop)

Y

1

/

4

"

Clearance

(Overhang)

X=

7

/

8

"

Y= Total
Countertop
Overhang

A

Control

panel

Check clearance for

control panel removal

MODEL SPECIFICATIONS TABLE

Table 1

E660i

E790i

E1060i

Main burner quantity
N/P orifi ce drill size

3

#42 / #54

3

#38 / #53

4

#40 / #53

Back burner quantity
N/P orifi ce drill size

1

#53 / #63

1

#51 / #57

2

#53 / #63

Smoker drawer burner
N/P orifi ce drill size

#68 / #77

#68 / #77

#68 / #77

Infrared searing burner

▲

N/P orifi ce drill size

#45 / #55

#45 / #55

#45 / #55

Echelon insulating liner model # (not included)*

3176-50

3186-50

3185-50

Power Supply Rating

120VAC / 1.5A / 60 Hz

Oven Lights Rating

12V / 10 watt halogen light bulb

A Countertop to unit bottom cut-out*

12"

12"

12"

B Side to side non-combustible cut-out*

31-

1

/

4

"

37"

50"

C Front to back non-combustible cut-out*†

23-

1

/

2

"

23-

1

/

2

"

23-

1

/

2

"

D Control panel width non-combustible cut-out‡

33"

38-

3

/

4

"

51-

3

/

4

"

REV 5 - 1412081445

L-C2-329

Advertising
This manual is related to the following products: