INSTALLATION REQUIREMENTS

Fig. 10-3 Clearance 'B' Diagram

Combustible

Min.

18"

(Clearance required for

right, left, and rear)

Fig. 10-2 Clearance 'A' Diagram

Non-combustible

Min.

4"

(Clearance required for

right, left, and rear)

Installation must be performed by a qualifi ed professional service
technician.

This grill is designed for outdoor use only. DO NOT use this grill inside
a building, garage, enclosed area, or under an unprotected overhead
combustible construction.

See below and the EXHAUST REMOVAL section on the following
page for details on installing under overhead construction.

DO NOT use this grill in or on a recreational vehicle or boat.

Important: This grill is not insulated. Refer to the information

below to ensure all required clearances are met.

The grill must have a minimum clearance of 18" from combustible
materials/items
AT ALL TIMES.

Overhead Construction Requirements (if applicable)

Non-combustible overhead construction: A 6 foot clearance is required
between the countertop and the construction above (Fig. 10-1).

Combustible overhead construction: A 6 foot clearance is required
between the countertop and the construction above. A vent hood
(see EXHAUST REMOVAL section) or an RHP combustible overhead
protection kit is required directly above the grill. See Fig. 10-1. RHP
vent hoods and protection kits are available, contact your local
dealer
.

Side and Rear Wall Clearances

For the minimum clearances between the grill and any side or rear
walls, your setup must fall within one (or more) of the following:

A. Clearance between grill and strictly non-combustible wall

(i.e. brick wall, see Fig. 10-2)

• The grill must have a minimum of 4" right, left, and rear

clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)

B. Clearance between grill and combustible wall

• The grill must have a minimum of 18" right, left, and rear

clearance from any combustible wall (see Fig. 10-4).

Fig. 10-1 Overhead requirements

Min.

6'

Combustible construction:

Requires vent hood or protection kit

Non-combustible construction:

Okay as-is

REV 0 - 1412011435