Fire Magic 36-VH Vent Hood User Manual

Page 9

Advertising
background image

REV 2 - 1502191555

L-C2-387

9

R O O F (8ft)

VENT PIPING
Install 10" round galvanized (single wall) vent piping as required.
Installation will depend on roof construction.

DUCT COVER

(To enclose transition and area above hood. Some installs may not
require a duct cover, as countertop height & roof height may vary. )

S
P

A
C

E

R

R

E

A

R

W

A

L

L

(N

O

N

C

O

M

B

U

S

T

I

B

L

E)

HOOD

Transition

GAS

GRILL

(rear of vent hood

must align with

rear of grill oven)

30-33"

Note: Drawings are not to scale.

Fire Magic offers a spacer and duct cover specifi cally designed for your vent hood. Reference the
information below for an overall orientation.
(Contact your dealer for ordering information.)

In order to use these prefabricated components, ensure the component dimensions allow for an appropriate
install as addressed below (as individual setups may vary).

REFER TO INSTALLATION SECTION FOR COMPLETE DETAILS REGARDING ALL INFORMATION FOUND ON THIS PAGE.

INSTALLATION REQUIREMENTS - FIRE MAGIC SPACER & DUCT COVER

(bracket)

• THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.

• Installation must be done by a qualifi ed professional service technician.

• Below is a diagram of a generic installation.

• Please review and understand this section prior to proceeding with installation.

Alternatively, a custom spacer and soffi t can be constructed that is appropriate for your individual setup.
See the following page for details.

The Spacer depth is based upon 8" between a non-combustible wall
and the rear of the grill (i.e. 4" backsplash + 4" required clearance).

The Duct Cover height is based upon a 33" - 36" countertop height
and an 8' high ceiling.

DUCT CO

VER

SP

ACER

8"

18"

Width varies

by model:

(36", 42", 48", 60")

20

1

/

4

"

12"

Width varies

by model:

(36", 42", 48", 60")