0 faults; causes and remedies – Flowserve N-Series Worthington User Manual

Page 13

Advertising
background image

N-SERIES OF THRUST POT USER INSTRUCTIONS ENGLISH 07/14

Page 13 of 20

5.0 FAULTS; CAUSES AND REMEDIES

FAULT SYMPTOM

Bearings have short life

PROBABLE CAUSES

POSSIBLE REMEDIES

MECHANICAL TROUBLES

Shaft bent.

Check shaft runouts within acceptable values

Rotating part rubbing on stationary part

internally.

Check for signs of this and consult Flowserve if necessary

Bearings worn

Replace bearings

Shaft running off center because of worn

bearings or misalignment.

Check misalignment and correct if necessary. If alignment satisfactory
check bearings for excessive wear

Excessive grease in ball bearings.

Check method of regreasing

Lack of lubrication for bearings.

Check hours run since last change of lubricant, the schedule and its
basis

Improper installation of bearings

Check method of assembly, possible damage or state of cleanliness
during assembly and type of bearing used

Damaged bearings due to contamination.

Check contamination source and replace damaged bearings

ELECTRICAL TROUBLES

Motor running too slow,

Check motor terminal box connections

Advertising