3 spare parts, 4 recommended spares, Ordering spare parts (6.3.1) – Flowserve WMV IDP User Manual

Page 17: Recommended spares (6.4), Replacement parts (6.3 and 6.4), Spare parts (6.3), Storage, spare parts (6.3.2)

Advertising
background image

WMV, WMVS USER INSTRUCTIONS ENGLISH 26999970 10-12

Page 17 of 28

flowserve.com

a) Check operating behaviour. Ensure noise,

vibration and bearing temperatures are normal.

b) Check that there are no abnormal fluid leaks

(static and dynamic seals).

c) Check that shaft seal leaks are within acceptable

limits.

d) Check running hours since last recharge of

grease or complete grease change. (Certain
motors only.)


6.2.2 Periodic inspection (six monthly)

a)

Check foundation bolts for

security of attachment and corrosion.

b)

Refer to the manuals of any associated

equipment for periodic checks needed.


6.2.3 Re-lubrication
For general guidelines refer to section 5.1, Lubrication.

6.2.4 Mechanical seals
When leakage becomes unacceptable the seal will
need replacement.

6.3 Spare parts


6.3.1 Ordering of spares
Flowserve keeps records of all pumps that have been
supplied. When ordering spares the following
information should be quoted:

1)

Pump serial number.

2)

Pump size.

3)

Part name

– taken from section 8.

4)

Part number

– taken from section 8.

5)

Number of parts required.


The pump size and serial number are shown on the
pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve. Any change to
the original design specification (modification or use
of a non-

standard part) will invalidate the pump’s

safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.

6.4 Recommended spares

Recommended spares are defined on the following
basis:

Class 1

– Start-up and commissioning spares.

Class 2

– Two year spares requirements

covering maintenance for this period.

Class 3

– Capital spares requirements.


Recommended spares are based on repair kits and
full replacement rotating assemblies as listed in the
following part numbers.

6.4.1 Repair kits - Class 1 and Class 2

Parts list supplied

Part no.

Part no.

Mechanical seal

KIT5&8WMV

KIT5&8WMVS

Shim x 2
Retaining ring
Screw, retaining ring
Balance drum
Balance drum bearing
O-ring x 2

Parts list supplied

Part no.

Part no.

Mechanical seal

KIT16WMV

KIT16WMVS

Shim x 2
Retaining ring
Screw, retaining ring
Balance drum
Balance drum bearing
O-ring x 2


6.4.2 Rotating assembly (fully assembled) – Class 3
The rotating assembly below comprises:

Mechanical seal

Retaining ring

Retaining ring screw

Balance drum

Set of impeller assemblies

Set of casing stage pieces

Coupling locating pin

Set of spacer shims

Set of O-rings

Balance drum bearing

(NB - pre-load cone is not included.)

Advertising