FAULTS; CAUSES AND REMEDIES

FAULT SYMPTOM

B e a r i n g s o v e r h e a t in g

B e a r i n g s h a v e s h o r t l if e o r a r e d a m a g e d

POSSIBLE CAUSES

POSSIBLE REMEDIES

A. SYSTEM TROUBLES

Incorrect oil level

Check and correct level after renewing
damaged bearings

Worn bearings

Replace bearings.

Water or foreign materials entering oil

Conduct oil analysis and CONSULT
FLOWSERVE, if necessary

Shaft running off center because of
worn bearings or misalignment.

Check misalignment and correct if
necessary. If alignment satisfactory
check bearings for excessive wear

Misalignment due to pipe strain

Check the flange connection and
eliminate strains using method
permitted

Oil film too thin or too thick

Check correct oil viscosity used for the
temperature

Rotating part rubbing on stationary part
internally

Check and CONSULT FLOWSERVE, if
necessary

Impeller out of balance resulting in
vibration and or creating excessive
loading to the thrust bearing

Check and CONSULT FLOWSERVE