6.14 Perform a dry fit of the collar on the sleeve.
6.15 Install the drive collar [58] onto the sleeve

assembly [1]. The drive collar may need to be

rotated so that the set screws [57] line up with

the large holes and quarter-dog set screws

[57.1] line up with the two smaller holes.

6.16 Install the setting devices and cap screws

[103] and [40] into the drive collar, engaging

with the gland [11]. See Figure 14.

6.17 While compressing seal by pushing down

on gland assembly [11], tighten the quarter-

dog set screws [57.1] to engage into the two

smaller holes of the sleeve assembly [1]. If

the seal does not contain quarter-dog set

screws then install the set screws [57] into the

sleeve [1]. See Figure 15.

Caution:

Over tightening will cause

distortion of the sleeve assembly [1]. Check

integrity of the sleeve with a plug of the

appropriate size to ensure no distortion has

occurred.

6.18 Install O-ring [19] into the ID groove of the

sleeve assembly. See Figure 16.

6.19 The cartridge seal assembly is now ready for

testing.

6.20 Adhere the gland gasket [18] to the gland

gasket surface with a spray adhesive such as

3M Super 77

®

. See Figure 17.

6.21 Permanently mark the seal type ISC2-BX or

ISC2-XB, seal size and gland ring material

clearly on the gland surface. See Figure 1

for placement location.

Figure 14

Figure 15

Figure 16

Figure 17

ISC2-BX

M060

C-276

Example

inch

marking

ISC2-BX

1.875

316 SS

Example

metric

marking