1 cartridge installation instructions, 2 recommendations – Flowserve SLM-6000 User Manual

Page 2

Advertising
background image

2

1 Cartridge Installation Instructions

The following instruction manual is designed to simplify the installation of a typical

SLM-6000 or SLM-6100 slurry seal. The SLM-6000 is a single seal with no quench port

connections, the SLM-6000 QCD adds an elastomer type quench containment device

(V-ring or lip seal) and 2 quench port connections to the single seal and the SLM-6100

adds a basic end face quench containment mechanical seal to make a tandem design

with a circulating device and 2 quench port connections to the single seal.

By reading this manual and following its guidelines, seal performance can be improved

by eliminating the chances of premature failure due to improper installation. In addition to

these instructions, consult the seal assembly drawing included for your specific seal design,

materials of construction, critical dimensions, and any auxiliary piping connections.

As you go through this manual you will find some of the instructions referenced with figure

numbers. These illustrations are provided to help you visualize what the instruction is trying

to explain. If these instructions are followed faithfully, the seal installation will be successful,

and maintenance personnel will understand the proper procedures to follow when pump

adjustment is necessary.

For special problems encountered during installation, contact your nearest Flowserve Sales

and Service Representative or Authorized Distributor.

Typical Single SLM-6000 Cartridge Seal Figure 1

Gland O-ring
Gland
Centering Plate
Centering Plate Locking Screws
Sleeve Collar
Collar Cap Screw
Snap Spring

Stator O-ring

Spring

Stator

Rotor

Rotor O-ring

Rotor Pin

Sleeve

Snap Ring
QCD Stator
V-ring
QCD Stator O-ring

Sleeve O-ring

Snap Ring

Flow Guide

2 Recommendations

To ensure that your SLM-6000 Mechanical Seal will provide you with the longest possible

life, we recommend the following:

2.1 New radial and thrust bearings be installed in the pump.

with QCD

(bottom view)

without QCD

(top view)

The images of parts shown in these instructions may differ visually from the actual

parts due to manufacturing processes that do not affect the part function or quality.

Advertising
This manual is related to the following products: