6

absorbed by the gaskets. Any remaining water may vaporize when exposed to

high product temperatures and damage gaskets. Rebuilding flexible graphite

gasketed seals after water testing is recommended to prevent this issue.

5

Operational Recommendations

5.1 The shaft speed and pressure and temperature in the seal chamber must

not exceed the maximum seal limits.

5.2 For seals using external cooling or flush, these fluids must be supplied

before startup and before product is introduced to the pump.

5.3 Avoid unnecessary valves in any seal support system. Critical fluid flow

will be stopped if these valves are inadvertently closed.

5.4 Single and dual non-pressurized (tandem) seals require adequate vapor

pressure margin in the seal chamber to prevent flashing of the product at

the seal faces.

5.5 Dual non-pressurized (tandem) seals require buffer fluid pressure below

seal chamber pressure at all times.

5.6 Dual pressurized (double) seals require barrier fluid pressure at least 2

bar (30 psi) above seal chamber pressure at all times. It is imperative to

pressurize the barrier fluid before pressurizing the equipment to prevent

product intrusion into the barrier system. Likewise, pressure must be

maintained on the barrier fluid until the equipment has been fully isolated,

depressurized and vented.

5.7 Ensure that the barrier/buffer fluid is clean and compatible with the prod-

uct. The buffer/barrier fluid must contain little or no additives for anti-wear/

oxidation. Automotive antifreeze should never be used. Flowserve can

provide information on barrier/buffer temperatures and flow requirements

based on product type, seal size, product temperature, barrier/buffer fluid

characteristics and shaft speed. Dual gas seals should use clean steam at

all times.

5.8 This seal is designed to resist corrosion by the product(s) listed on the

assembly drawing. Do not expose the seal materials to products other

than those shown on the assembly drawing. The seal assembly drawing

lists the materials of construction. Consult your Flowserve representative

when in doubt or when using the seal for another application than

for which it was selected.

5.9 Liquid seal requirements:

5.9.1 Do not start the equipment dry.

5.9.2 Vent all air and/or product vapor from the equipment casing and

the seal chamber before startup. Vent casing and tubing of heat

exchanger (if applicable).