3 seal barrier gas supply, 4 md-200 seal piping, Recommended piping for dual conditioned gas seal – Flowserve MD-200 Series Durametallic User Manual

Page 5: Figure 2

Advertising
background image

5

3 Seal Barrier Gas Supply

The standard MD-200 seal design, using #22 carbon rotor faces, is

engineered to operate with non-humidified gas supplied to the seal

chamber at a consistent pressure 2 bar (25 psig) above the maximum

vessel pressure. Nitrogen gas is the barrier fluid of choice. The gas to be

used, maximum vessel pressure, shaft speed, temperature, equipment

and shaft size must be specified when the seal is ordered.

Note: MD-200 seal designs using #5 carbon rotor faces, still require a

conditioned or humidified barrier gas. Nitrogen gas, humidified with a

polar compound (water), is the barrier fluid of choice.

4 MD-200 Seal Piping

4.1 Install piping for the clean nitrogen to the canister tap. A filter,

pressure regulator, flow meter, check valve and pressure indicator

are recommended.

Note: A conditioner or humidifier is recommended when using MD-200

with #5 Carbon rotor faces.
4.2 Bearings (optional) have been pre-lubricated during seal assembly.

Recommended Piping for Dual Conditioned Gas Seal

Figure 2

Check

Valve

N

Source

Pressure

Regulator

Pressure

Indicator

Bypass

Humidifier

(optional: use only with

#5 carbon rotor faces)

Flow

Meter

Barrier

Gas

Inlet

2

Filter

Advertising