5 seal operation – Flowserve MD-200 Series Durametallic User Manual

Page 6

Advertising
background image

6

5 Seal Operation

To assure reliable operation of this sealing product, the following

operating guidelines should be observed.

5.1 Maintain the gas (non-conditioned or conditioned) supply

pressure

both while the seal is operating and when the equipment

is on standby. Always ensure that there is an adequate flow of

barrier gas to the seal.

5.2 Do not exceed the maximum barrier pressure specified for the

seal design. The barrier pressure should be 2 bar (25 psig) above

the operating vessel pressure.

5.3 Do not exceed the maximum vessel pressure specified for the

application. This could reduce the recommended vessel to barrier

differential pressure which could adversely affect seal performance.

5.4 Do not exceed the maximum vessel temperature specified for

the application. This could exceed the temperature limits of the seal

materials of construction applied to the application.

5.5 Do not exceed the seal material corrosion limits. This seal was

designed for the application shown on the seal assembly drawing.

Do not exceed the limits of the material alloys and elastomers

supplied in its construction.

For special problems encountered during installation, contact your

nearest Flowserve Sales and Service Representative or Flowserve

Authorized Distributor.

Advertising
This manual is related to the following products: