4 Operational Recommendations

4.1 Do not exceed corrosion limits. The CPM PX seal is designed

to resist corrosion by most chemicals. However, do not expose

the CPM PX materials of construction to products outside of their

corrosion limits. Consult Flowserve, Flow Solutions for assistance.

4.2 Do not exceed the Pressure limits of the CPM PX seal, consult

Flowserve Flow for assistance.

4.3 Do not exceed the temperature limits of the CPM PX seal. The

materials of construction are listed on the box label. Turn on cooling

water to the supply tank before start up if the tank has coils.

For special problems encountered during installation, contact your

nearest Flowserve Sales and Service Representative or Authorized

Distributor.

5 Repair

This product is a precision sealing device. The design and dimension

tolerances are critical to seal performance. Only parts supplied by

Flowserve should be used to repair a seal. To order replacement parts,

refer to the part code and B/M number. A spare backup seal should be

stocked to reduce repair time.
When seals are returned to Flowserve for repair, decontaminate the

seal assembly and include an order marked "Repair or Replace." A

signed certificate of decontamination must be attached. A Material

Safety Data Sheet (MSDS) must be enclosed for any product that

came in contact with the seal. The seal assembly will be inspected and,

if repairable, it will be rebuilt, tested, and returned.