Disassembly

When disassembling seal, inspect for conditions which may have caused the
need for the seal to be removed from service. If seal was removed due to
premature failure, determine what conditions caused that failure and correct any
problems prior to returning the repaired seal to service. For assistance with seal
failure analysis, please contact your Flowserve representative.

2

© Copyright 2001 Flowserve Corporation

These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in
personal injury or death to personnel and damage to the equipment.

1

Nomenclature

Figure 1

Seal Parts that are always replaced

• Rotary unit R
• Mating ring 3
• All O-rings P 11
• Gland gasket G
• Bellows vibration dampener M
• Centering tabs CT and cap screws K
• Cup point and quarter dog set screws 13 13A

Table 1

Reconditionable Seal Parts

• Gland assembly 1
• Sleeve 10
• Sleeve collar 9

Note: Rotary unit (R) consists of

elastomer bellows rotary unit
and single coil spring.

R

Rotary Unit

3

Mating Ring

P

Mating Ring O-ring

11

Shaft O-ring

G

Gasket

1

Gland Assembly

1B

Gland Drive Ring

B

Carbon Bushing

CT

Centering Tab

K

Centering Tab Cap
Screw

10

Sleeve

M

Bellows Vibration
Dampener

9

Sleeve Collar

13

Cup Point Set Screw

13A

Quarter Dog
Set Screw

R

3

M

13

9

1

11

10

G

1B

P

B

13A

CT

K

Advertising