Rotor Assembly Installation

1. Lightly lubricate the rotor O-ring inside diameter with the silicone grease provided with

the BGM

Dura Seal

.

2. Break the sharp edges of shaft keyways or grooves using a file, emery cloth, etc., to

protect the O-ring from being cut or nicked.

3. Use silicone grease to lightly lubricate the shaft that the BGM rotor has to slide over.

To first obstruction

Face of seal housing to be square
to the axis of the shaft
to within 0.005" (0.13mm) FIM

Shaft or sleeve OD
+0.001" (+0.03mm)
-0.002" ( -0.05mm)

Housing

Bore

±

0.001

or

+0.000"

-0.002"

Bearings must be in good condition

Maximum lateral or axial movement of shaft (end play) 0.015" FIM

Housing bore to be concentric with shaft 0.003" FIM

Maximum dynamic shaft deflection at face of housing 0.002" FIM

Stator O-Ring

Rotor

Stator

Rotor O-Ring

4. Gently slide the rotor along the shaft so that the rotor face seats against the stator face.

Make certain the silicone lubricant does not get on the seal face.

5. Use light finger pressure to ensure the seal faces are making contact.

6. Hold the shaft stationary and rotate the rotor a minimum of one revolution to evenly spread

out the silicone grease.