1 equipment check, Seal chamber requirements – Flowserve Single Outside Seal User Manual

Page 2

Advertising
background image

2

Seal Chamber Requirements

Figure 1

1 Equipment Check

1.1 Follow plant safety regulations:

• lock out motor and valves.

• wear designated personal safety equipment.

• relieve any pressure in system.

• consult plant MSDS files for hazardous material regulations.

1.2 Disassemble equipment to allow access to seal installation area.

1.3 Remove all burrs and sharp edges from the shaft or sleeve

including sharp edges of keyways and threads. Replace worn shaft

or sleeve. Make sure the seal housing bore and face are clean and

free of burrs.

1.4 Check requirements for shaft, sleeve, and seal housing.

See Figure 1.

1.5 Check assembly drawing included with the seal for specific

seal design, materials of construction, dimensions, and piping

connections.

To first obstruction

Face of seal housing to be square to the axis

of the shaft to within 0.013 mm per millimeter

(0.0005 inches) of seal chamber bore FIM and

have a 1.6

μ

m (63

μ

inch) R finish or better

a

Gland pilot can be at either of these

register locations, concentric to within

0.13 mm (0.005 inch) FIM of shaft or sleeve OD

Seal housing bore to have 3.2 μm

(125 μinch) R finish or better

Sleeve or shaft finish to be

0.8 μm (32 μinch) R or better

a

a

Shaft or sleeve OD

+0.000 mm (+0.000 inch)

-0.050 mm (-0.002 inch) ANSI

+0.000 mm (+0.000 inch) API 610/682

-0.025 mm (-0.001 inch) DIN/ISO

• Bearings must be in good condition

• Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) FIM

• Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) FIM

• Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) FIM

Advertising