1.6 Check shaft or sleeve OD, box bore, box depth, and distance

to the first obstruction to ensure that they are dimensionally the

same as shown on the seal assembly drawing.

1.7 Check gland pilot and bolt holes to ensure they are adaptable

to the equipment and are the same as shown on the assembly

drawing.

1.8 Handle all seal parts with care, they are manufactured to precise

tolerances. The seal faces; rotating seal face and stationary seal

face are of special importance. These two sealing faces are lapped

flat to within three light bands (34.8 millionths of an inch).

Keep the seal faces perfectly clean at all times.

Single Outside Seal Installation

2 Single End Suction Vertical Split Case and Vertical

In-Line Pumps (1 box)

2.1 Lubricate the shaft or sleeve lightly with silicone lubricant

provided with the seal before installing any seal parts.

2.2 Install the rotating face gasket O-ring into the bore of the

rotating seal face.

2.3 Engage the rotating assembly consisting of the spring holder,

springs, and seal drive with the rotating face to form the rotating

assembly. Be sure any drive pins in the seal drive engage the slots

in the rotating face. Handle PTFE U-cup rings and graphite rotating

face gaskets with extreme care. U-cup rings must be assembled

individually and not pushed on the shaft or sleeve while they are

part of the rotating face or rotating assembly. Avoid nicking or

pinching either lip on the U-cup rings. Use both U-cup rings,

they work together to form an effective seal.

2.4 Install the rotating seal parts spring holder first onto the shaft or

sleeve in the proper sequence with the face of the rotating face

facing the impeller. Use a slight twisting motion for any complete

rotary unit containing O-ring rotating face gaskets. Place rotating

assembly unit as close as possible to the first obstruction, usually

the radial bearing.