Dual Inside Seal with Induced Circulation

Through Supply Tank with Cooling Coil Figure 1

Plan 53A/ANSI Plan 7353A

Pressure source

4 feet (1.2 m)

maximum

1.5 - 2 feet

(0.45 -0.6 m)

minimum

Orifice

option

Bypass line

from pump

discharge

Supply

tank

assembly

normally open

Level switch (low)

Pressure

switch

(low)

Pressure

indicator

Cooling

coils

Drain

normally

closed

Plan 53B/ANSI Plan 7353B

What

Pressurized barrier fluid circulation

through reservoir.
Fluid is circulated by a pumping ring

in the dual seal assembly

What

Pressurized barrier fluid circulation

with bladder accumulator.
Fluid is circulated by a pumping ring in

the dual seal assembly.

Why

Isolate process fluid.
Zero process emissions.
Higher pressure than Plan 53A.

Plan 53C/ANSI Plan 7353C

What

Pressurized barrier fluid circulation with

piston accumulator.
Fluid is circulated by a pumping ring in

the dual seal assembly.

Why

Isolate process fluid.
Zero process emissions.
Higher pressure than Plan 53A.
Dynamic tracking of system pressure.

Why

Isolate process fluid
Zero process emissions
Typically used <150 psig (10.3 bar) pressure