Flowserve Seal Support Reservoir User Manual

Page 4

Advertising
background image

API Plan 52/ANSI Plan 7252 for dual unpressurized seals

An API Plan 52/ANSI Plan 7352 is an unpressurized dual seal system which

is used in services where no leakage to atmosphere is tolerated. The system

consists of dual mechanical seals with a buffer fluid between the seals. The

buffer fluid is contained in the seal pot which is vented to a flare, thus maintaining

the buffer fluid pressure close to atmosphere. Primary (inboard) seal leakage will

be product leakage into the buffer fluid. There will always be some leakage.
An API Plan 52/ANSI Plan 7352, Figure 2, works best with clean, non-polymeriz-

ing products which have a vapor pressure higher than the buffer fluid pressure.

These products will flash in the supply tank and the vapor can escape to the vent

system. If the product has a vapor pressure lower than the buffer fluid or supply

tank pressure, the leakage will remain a liquid and will cause the barrier fluid level

to rise.
Should excessive primary (inboard) seal leakage not be detected early, the

heavier process fluid will displace the buffer fluid and can result in increased

seal wear.

4

Dual Unpressurized Seal with Induced Circulation

Through Supply Tank with Cooling Coils Figure 2

API Plan 52/ANSI Plan 7352

4 feet (1.2 m)

maximum

1.5 - 2 feet

(0.45 -0.6 m)

minimum

Orifice

option

Bypass line

from pump

discharge

Supply

tank

assembly

Level switch (high)

Level switch (low)

Pressure

switch

(high)

Pressure

indicator

Cooling

coils

Drain

normally

closed

To flare

or vapor

recovery

Advertising