Description, 1 equipment check – Flowserve 80 Series Five Star Seal User Manual

Page 2

Advertising
background image

Description

The 84/85 seals are cartridge mounted mechanical seals, designed for

ease of installation and reliable operation. No seal setting dimensions

are required. Rotatable setting devices provide proper alignment. The

flexible stationary face design compensates for inadvertent misalignment

of the seal chamber face. Multiple springs provide uniform face loading

and are external of the pumpage, resisting clogging or hang-up. Installa-

tion according to the following steps will assure long trouble free life of

the 84/85 seals.

1 Equipment Check

1.1 Follow plant safety regulations prior to equipment disassembly:

• lock out motor and valves.

• wear designated personal safety equipment.

• relieve any pressure in the system.

• consult plant MSDS files for hazardous material regulations.

1.2 Disassemble equipment in accordance with equipment

manufacturer’s instructions to allow access to seal installation area.

1.3 Remove existing mechanical seal and gland or compression

packing and packing gland.

1.4 Make sure the shaft or sleeve and the seal housing face are

clean and free of burrs, cuts, dents, or corrosion that might cause

leakage past the sleeve gasket O-ring or gland gasket. See

Figures 1 & 2. Replace worn shaft or sleeve if it is worn in the

sleeve gasket area. Remove sharp edges from keyways and

threads.

1.5 Check equipment dimensions to ensure that they are within the

dimensions shown in Figures 1 and 2. Critical dimensions include

shaft or sleeve OD (A), a chamber depth of at least dimension (G),

minimum and maximum seal housing bore (C), and the minimum

distance to the first obstruction (K). See Figure 2.

2

The images of parts shown in these instructions may differ visually from the actual

parts due to manufacturing processes that do not affect the part function or quality.

Advertising