2.5 Position the 84/85 with the gland tight against the seal chamber
face. Turn the gland so that the flush tap is as close to the 12:00
o’clock position as possible and so that the flush piping will clear the
bearing frame. Tighten the gland nuts evenly in a diagonal
sequence. Do not overtighten the gland nuts, as this can warp
seal parts and cause leakage.
6
Figure 5
Figure 6
2.6 Assemble the pump.
Avoid pipe strain.
Align coupling properly.
2.7 With the impeller, shaft,
coupling, and bearings in
their final operating positions,
tighten the 84/85 set screws.
See Figure 5.
2.8 Rotate the setting devices
180° from the drive collar and
retighten. See Figure 6.
Loosen the hex head bolts in
the bronze centering tabs,
rotate 180° to clear the drive
collar. Retighten the hex head
bolts to store the setting device
on the gland.
2.9 Turn the shaft by hand to
ensure unobstructed operation.
2.10 See Operational
Recommendations
before start-up.