Indicators, Specifications, Rj-45: mdi – Digi MIL-170TRM User Manual

Page 4: Rj-45: mdi-x

Advertising
background image

Install Guide

Model: MIL-170TRM

4

The following table shows which Link Sentry feature is enabled:

Note:

For two MIL-170s used back-to-back and UTP-to-UTP, all DIP switches must be

enabled

(in the “down” position) on the first MIL-170. On the second MIL-170, enable switches 1
and 4 (in the “down” position).

Default setting for Link Sentry: All switches set in the “up” position (disabled). When using
the SNMP module to control the Link Sentry feature, leave the switches in the default
mode (“up”).

I n d i c a t o rs

There are four LEDs, including:

TP/ACT

: Receiving packets from the 10BASE-T port

TP/LINK

: There is an active connection on the 10BASE-T port

FX/LINK

: There is an active connection on the 10BASE-FL port

FX/ACT

: Receiving packets from the 10BASE-FL port

S p e c i fi c a t i o n s

R J - 4 5 : M D I

• Pin 1 = Transmit Data +

• Pin 2 = Transmit Data -

• Pin 3 = Receive Data +

• Pin 6 = Receive Data -

R J - 4 5 : M D I - X

• Pin 1 = Receive Data +

• Pin 2 = Receive Data -

• Pin 3 = Transmit Data +

• Pin 6 = Transmit Data -

Table 1: Link Sentry Features

Switch

Losing Link on RX of

Stop sending Link on TX of

1 (down)

Fiber port

Fiber port

2 (down)

UTP port

UTP port

3 (down)

UTP port

Fiber port

4 (down)

Fiber port

UTP port