Troubleshooting valdisk 150 valves – Flowserve BX 150 User Manual

Page 7

Advertising
background image

37-7

Failure

Probable Cause

Corrective Action

Valve moves to failure

1. Failure of actuator O-ring

1. Replace actuator stem O-ring

position, excessive air

2. Failure of sliding seal assembly

2. Repair or replace sliding seal assembly

bleeding from transfer case

Jerky shaft rotation

1. Overtightened packing

1. Retighten packing box nuts to slightly over

finger-tight for V-ring packing, 14 ft-lbs for
braided packing

2. Improper adjustment of lever arm on

2. Readjust lever arm (see step 1 in the

shaft causing arm to contact transfer case

“Remounting Actuator” section)

3. Cylinder wall not lubricated

3. Lubricate cylinder wall with silicone lubricant

4. Worn piston O-ring allowing piston to

4. Replace O-ring; if galling has occurred

gall on cylinder wall

replace all damaged parts

5. Worn actuator stem O-ring causing

5. Replace O-ring; if actuator stem is galled

actuator stem to gall on stem collar

replace it

6. Worn (or damaged) thrust bearings, shaft 6. Disassemble and inspect parts; replace

bearings or packing followers

any worn or damaged parts

Excessive leakage

1. Improper adjustment of external stroke

1. See “Remounting Valve to Actuator”

stops

section

2. Worn or damaged seat

2. Replace seat

3. Damaged disc seating surface

3. Replace disc

4. Improper handwheel adjustment acting

4. Adjust handwheel until disc seats properly

as limitstop

Leakage through line

1. Dirty line gasket surfaces

1. Clean gasket surfaces and reinstall valve

2. Improper sealing of line flanges

2. Tighten line flanges evenly and

completely (see Table 1 for proper torque)

3. Flange or pipe misalignment

3. Clean body bore and stem, replace packing

Leakage through

1. Loose packing box nuts

1. Tighten packing box nuts to slightly over

packing box

finger-tight for V-ring packing, 14 ft-lbs for
braided packing

2. Worn or damaged packing

2. Replace packing

3. Dirty or corroded packing

3. Clean body bore and stem, replace packing

Disc interferes with body

1. Disc installed upside down

1. Reinstall disc

2. Worn thrust bearings

2. Replace thrust bearings

Disc interferes with line

1. Cement lining or heavy schedule pipe

1. Modify line to allow proper disc clearance

Valve slams, won’t open,

1. Improper valve installation

1. See step 2 in “Installation” section and

or causes severe water

correct flow direction

hammer

Shaft rotates, disc remains

1. Missing or broken taper pin

1. Replace taper pin

open or closed

2. Broken shaft

2. Replace shaft, make sure disc does not

overstroke and contact disc stop

Actuator operates, shaft

1. Broken internal actuator parts

1. Refer to appropriate actuator Maintenance

does not rotate

Instructions

Troubleshooting Valdisk 150 Valves