9.0

MAINTENANCE INSTRUCTIONS


9.1

DISASSEMBLY and REASSEMBLY


The following instructions cover the disassembly and reassembly of the ½”-
2” Y- Globe valves.

WARNING

Prior to performing disassembly, close off the line pressure to

the valve, and release all pressure in the valve.

Extreme care should be taken to ensure that the lower stem (025) and disc
(004) do not separate when removed as one unit until both are adequately
supported. Failure to do so may cause the disc to fall off the stem, and may
cause damage to the disc and/or injury to personnel.


After removal of the disc from the valve, care should be taken to protect the
seating surface from damage. The disc should be placed in a clean area
until it is ready for replacement. THE SLIGHTEST NICK OR SCRATCH ON
A SEATING SURFACE MAY PREVENT COMPLETE SHUTOFF AND
NECESSITATE EXTENSIVE REWORK OR REPLACEMENT.

9.1.1 Valve Disassembly (Refer to figure 1 for reference part numbers)

(1)

Relieve pressure from valve.

(2)

Place the valve in the closed position and then open the tee-
handle (175) 1-2 revolutions.

(3)

Remove

the

Handwheel

Nut (240) from the Upper Stem

(024).


(4)

Remove

the

Tee-Handle

(175) and Thrust Washer (147) from

the upper stem.


(5)

Remove

the

Gland

Stud

Nuts (234), and then remove the

corresponding Gland Studs (205).


(6)

Remove

the

Stanchion

Capscrews (280) and Stanchion

Lockwashers (251).


(7)

Remove

the

Yoke

Cap

(019). Remove the Thrust Washers

and Needle Bearing (168) (356) if applicable. Rotate the Yoke
Sleeve (017) in a counterclockwise direction to remove it from
the Upper Stem (024)


(8)

Remove

the

Stanchions (427) from the Body (001).

8