MAINTENANCE INSTRUCTIONS (Continued)


(9)

Loosen

the

Stem

Clamp

Setscrews (221) and remove the

Stem Clamp (029) and Stem Clamp Key (255).


(10)

Lift

the

Flange

Gland

(133) upward and remove the Packing

(110, 112) from the stuffing box. Removal of the packing is
best accomplished with a packing hook or similar device.


(11)

Loosen

the

Gland

Retainer Setscrews (220) until they do not

make contact with the Gasket Retainer (033). Then turn the
Gland Retainer (131) counterclockwise off the Bonnet (002).
Turn the Gasket Retainer (033) out of the Body (001).


Note: The bellows is seal welded to the bonnet and stem and is an

assembly. The assembly is referred to as a Rapid Change Kit,
and is comprised of all trim parts, stem, bellows, bonnet, and
pressure seal gasket. The Rapid Change Kit is a complete
assembly and must be removed and replaced as such.


(12)

Remove

the

Pressure

Seal

Gasket (030) by carefully lifting the

Upper Stem (024), (including the attached bellows assembly)
from the Body (001). It is imperative that the bellows
assembly be lifted out of the body as straight as possible to
eliminate the possible scoring of the stem. If the bonnet is
wedged into position, carefully lift up on the stem until the
gasket and bonnet come free.


Note:

The

Disc

(004)

and

Disc

Skirt (005) are attached to the stem

by the use of a Stem Retainer (028) and Disc Skirt Pin (265).


(13)

The

Disc

(004),

and

Disc Skirt (005), can now be removed

from the stem.

WARNING


Be

careful

when

removing the assembly from the valve body.

After removal from the valve, care should be taken to protect the
seating surface of the disc from damage. The disc should be
placed in a clean area until ready to replace in the valve. THE
SLIGHTEST NICK OR SCRATCH ON A SEATING SURFACE MAY
PREVENT COMPLETE SHUTOFF AND NECESSITATE
EXTENSIVE REWORK OR REPLACEMENT


(14)

Remove

the

Disc

Skirt

Pin (265) from the Skirt (005).

Unthread the Disc (004) from the Disc Skirt (005). Place the
disc (004) where it won’t become damaged or scratched.
Remove the Stem Retainer (028) and Disc Skirt (005).

9