10.

Attach the new piezo assembly to base of
modulator, installing and tightening the 9/64”
Allen screw opposite the wiring entry first, and
then installing and tightening Allen screws A and
B. All Allen screws should be installed hand
tight.














11.

Reconnect the flexible tubing to the barbed
fitting by hand.












12.

Insert the red and black piezo assembly
connector back through the housing, and attach
to the main PCB assembly, assuring the
connection is tight.

B

A