Technical Manual

Disassembly instructions T4E

For all jobs which are to be carried out on an installed valve, the works safety requirements and

the general accident prevention instructions must be observed. Moreover, the general installation

and maintenance instructions for atomac fluorcarbon resin lined valves must be considered.

1. Prior to disassembly, the valve must be cleared of all fluid according to the

above-mentioned instructions. Particular care must be taken that during rinsing and

draining of the piping, the valve is opened and closed repeatedly. These cycles (open-

ing and closing) are to be repeated during draining of the piping. Only when following this

procedure, is it ensured that all remaining pressure inside the body is eliminated.

2. For disassemble the valve put the body on a work bench with a soft cover (rubber mat).

3. Disassemble the wrench by removing the bolt

(190) and washer (180).

4. By pushing up the stop collar

(130) the stop collar retainer (140) can easily be removed.

5. Unscrew the top cap bolts

(100) and remove the top cap (080) from the body (010).

6. Turn the plug

(020) several timer to make it move upwards.

7. Remove the grounding spring

(070), thrust gland (060), metal diaphragm (050) (optional)

and the

PFA diaphragm

(040).

8. If necessary the stop

(110) can be removed

by unscrew the stop fasteners

(120).