T4e - recommended tightening torques, Technical manual – Flowserve T4E Durco Lined Plug Valve IOM User Manual

Page 13

Advertising
background image

T4E - PFA lined Plug Valve

Ahaus GmbH

von-Braun-Straße 19a

D-48683 Ahaus

Postfach 1162 D-48661 Ahaus

Telefon: +49(0) 2561-686-100

Fax: +49(0) 2561-686-200

Register:

18

Page:

13

Date:

03.2004

Revision: 02.2007

Technical Manual

T4E1 and T4E2 - Recommended

tightening torques* (150lbs a. PN16)

* maximum valve

top cap bolts

adjuster bolts

T4E3 - Recommended tightening torques*

(300lbs)

* maximum valve

top cap bolts

adjuster bolts

DN

(100)

(090)

Nm

in.lbs

Nm

in.lbs

015

½“

-

-

-

-

020

¾“

-

-

-

-

025

1“

10

89

4

35

040

1½“

10

89

4

35

050

2“

18

159

4

35

080

3“

33

292

6

53

100

4“

44

389

8

71

150

6“

70

620

17

150

200

8“

108

956

14

124

250

10“

165

1460

50

443

300

12“

150

1328

50

443

DN

(100)

(090)

Nm

in.lbs

Nm

in.lbs

½“

-

-

-

-

¾“

-

-

-

-

1“

14

124

4

35

1½“

14

124

4

35

2“

27

239

4

35

3“

48

425

6

53

4“

84

743

8

71

6“

150

1328

17

150

8“

150

1328

14

124

Advertising