T4e - recommended tightening torques, Technical manual – Flowserve T4E Durco Lined Plug Valve IOM User Manual
Page 13
T4E - PFA lined Plug Valve
Ahaus GmbH
von-Braun-Straße 19a
D-48683 Ahaus
Postfach 1162 D-48661 Ahaus
Telefon: +49(0) 2561-686-100
Fax: +49(0) 2561-686-200
Register:
18
Page:
13
Date:
03.2004
Revision: 02.2007
Technical Manual
T4E1 and T4E2 - Recommended
tightening torques* (150lbs a. PN16)
* maximum valve
top cap bolts
adjuster bolts
T4E3 - Recommended tightening torques*
(300lbs)
* maximum valve
top cap bolts
adjuster bolts
DN
(100)
(090)
Nm
in.lbs
Nm
in.lbs
015
½“
-
-
-
-
020
¾“
-
-
-
-
025
1“
10
89
4
35
040
1½“
10
89
4
35
050
2“
18
159
4
35
080
3“
33
292
6
53
100
4“
44
389
8
71
150
6“
70
620
17
150
200
8“
108
956
14
124
250
10“
165
1460
50
443
300
12“
150
1328
50
443
DN
(100)
(090)
Nm
in.lbs
Nm
in.lbs
½“
-
-
-
-
¾“
-
-
-
-
1“
14
124
4
35
1½“
14
124
4
35
2“
27
239
4
35
3“
48
425
6
53
4“
84
743
8
71
6“
150
1328
17
150
8“
150
1328
14
124