2. Storage

General

The PMV positioner is a precision in-

strument. Therefore it is essential that it is
handled and stored in the correct way.
Always follow the instructions below!

N.B. As soon as the positioner is

connected and started, an internal air bleed
will provide protection against corrosion
and prevent the ingress of moisture. For this
reason, the air supply should always be kept
on.

Storage indoors

Store the positioner in its original

packaging. The storage environment must
be clean, dry and cool, (15 to 26

°C,

59 to 79

°F).

Storage outdoors or for a
longer period

If the positioner must be stored

outdoors, it is important that all the cover
screws are tightened and that all connections
are properly sealed. The unit should be
packed with a desiccant in a plastic bag or
similar, covered with plastic, and not exposed
to sunlight, rain, or snow.

This is also applicable for long-term

storage (more than 1 month) and for long
transport by sea.

Storage in a warm place

When a positioner is stored in a warm

place with a high relative humidity and is
subjected to daily temperature variations, the
air inside the unit will expand and contract.

This means that air from outside the unit

may be drawn into the positioner. Depending
on the temperature variations, relative
humidity, and other factors, condensation and
corrosion can occur inside the unit, which in
turn can give rise to functional disorders or
a failure.