Installation – Flowserve NRG 111-11 User Manual

Page 12

Advertising
background image

12

Attention

The seating surfaces of the standpipe or the flange provided on the vessel must be
accurately machined, see fig. 6.

Do not bend electrode tip when mounting.

Use only ring joint (of stainless steel 1.4301) D 33 x 39 DIN 7603 supplied with the
electrode.

Do not lag electrode body above the hexgonal section.

Do not insulate electrode thread with hemp or PTFE tape.

The leakage path between electrode and flange (mass) must be at least 14 mm, fig. 5

Observe minimum distances and spacing dimensions when installing the electrode,
fig. 5

Installation

NRG 111-11, step 1

1. Screw electrode tip D into measuring electrode A. Fig. 3

2. Carefully determine required measuring length of electrode. Observe min. length, Fig. 2

3. Mark length of electrode tip D.

4. Unscrew electrode tip D from measuring electrode A and cut tip.

5. After visual inspection screw electrode tip D into measuring electrode A. Slide spring C along

electrode tip D, so that its bent end completely enters into small bore B.

6. Fit surface extension disk E to electrode tip end and make sure that electrode tip protrudes 2 mm

beyond the bottom of the surface extension disk. Fix the surface extension disk in this position with
the grub screw G. Push lock washer F over electrode tip end against surface extension disk E.

NRG 111-11, step 2

1. Check seating surfaces. Fig. 6

2. Place joint ring E onto seating surface F of electrode. Fig. 4

3. Apply a light smear of silicone grease G (e. g. Molykote

®

111) to electrode thread.

4. Screw level electrode into threads or flange provided on vesssel and tighten with a 41 mm open-end

spanner. The torque required is 475 Nm when cold.

Molykote

®

111 is a registered trademark of DOW Corning Corp., Midland Michigan, USA