Installation – Flowserve NRG 111-11 User Manual

Page 12

Advertising
background image

12

Attention

■

The seating surfaces of the standpipe or the flange provided on the vessel must be
accurately machined, see fig. 6.

■

Do not bend electrode tip when mounting.

■

Use only ring joint (of stainless steel 1.4301) D 33 x 39 DIN 7603 supplied with the
electrode.

■

Do not lag electrode body above the hexgonal section.

■

Do not insulate electrode thread with hemp or PTFE tape.

■

The leakage path between electrode and flange (mass) must be at least 14 mm, fig. 5

■

Observe minimum distances and spacing dimensions when installing the electrode,
fig. 5

Installation

NRG 111-11, step 1

1. Screw electrode tip D into measuring electrode A. Fig. 3

2. Carefully determine required measuring length of electrode. Observe min. length, Fig. 2

3. Mark length of electrode tip D.

4. Unscrew electrode tip D from measuring electrode A and cut tip.

5. After visual inspection screw electrode tip D into measuring electrode A. Slide spring C along

electrode tip D, so that its bent end completely enters into small bore B.

6. Fit surface extension disk E to electrode tip end and make sure that electrode tip protrudes 2 mm

beyond the bottom of the surface extension disk. Fix the surface extension disk in this position with
the grub screw G. Push lock washer F over electrode tip end against surface extension disk E.

NRG 111-11, step 2

1. Check seating surfaces. Fig. 6

2. Place joint ring E onto seating surface F of electrode. Fig. 4

3. Apply a light smear of silicone grease G (e. g. Molykote

®

111) to electrode thread.

4. Screw level electrode into threads or flange provided on vesssel and tighten with a 41 mm open-end

spanner. The torque required is 475 Nm when cold.

Molykote

®

111 is a registered trademark of DOW Corning Corp., Midland Michigan, USA