Flowserve BK 15 User Manual

Page 7

Advertising
background image

7

Pressure /Temperature Ratings PN 40

Body material

Forged steel 1.0460 (P250GH / C22.8) / ASTM A105

Nominal sizes (DN)

40, 50

Connections

Flanged to DIN PN 40

Service pressure PMA [barg]

40

35

28

21

14.5

[psig]

580

508

406

305

210

Related temperature TMA [°C]

20

200

300

400

450

[°F]

68

392

572

752

842

Technical Data

Explanatory Notes

Scope of Supply

BK 15
1 Steam trap type BK 15
1 Installation manual

Description

Thermostatic/thermodynamic steam trap with corrosion-resistant regulator unaffected
by waterhammer. The Duo stainless steel regulator is externally adjustable. With
integral strainer and non-return valve action. Asbestos-free cover gasket (graphite).
Installation in any position.

The steam trap is adjusted at our factory to discharge condensate with virtually no
banking-up. More undercooling (banking-up of condensate) can be manually adjusted
during operation from the outside.

Function

During start-up of the plant the Duo stainless steel plates are flat. The service
pressure acts in the opening direction, the valve is completely open. As the
condensate temperature rises, the plates deflect, drawing the stage nozzle towards
the closed position. As the condensate temperature sinks, the deflection of the Duo
stainless steel plates decreases and the steam trap opens at the adjusted opening
temperature.

The thermostatic and spring characteristics of the stack of plates are balanced such
that condensate is always discharged at a given undercooling temperature.
The trap provides automatic air-venting at start-up and during operation. The correct
functioning of the BK 15 is neither affected by upstream pressure variations nor by
back pressure. The BK 15 can also be used for thermal air-venting in steam systems.

Advertising