Nordstrom Figure 50165 and 50169 Dynamic Balance Iron Plug Valve FCD NVENIM2006-00 – 09/05

flowserve.com

Technical Data: Procedure

for Tightening Cap Screws

note: This procedure is intended only as a guide. It is impossible for Flowserve Sulphur Springs Opera-
tions to know actual field-site conditions, so your judgement and experience must be exercised.

1. Inspect applicable parts to be sure that:

a) Tapped holes are clean, dry, and free of foreign matter.

b) Threads are free of nicks, grit, and burrs.

2. Apply a quality thread lubricant on the threads of the Cap Screws/Nuts, or the tapped holes, and the

contact face of the Cap Screws/Nuts.

3. Install all Cap Screws/Nuts by hand. Engage the threads at least 1/2 of the diameter before using a

wrench.

4. Hand-tighten the first four Cap Screws/Nuts in the sequence shown in Diagram 1. This is to avoid

cocking the parts.

5. Tighten the Cap Screws in a crisscross pattern. Tighten them first to the 10% torque value, then in a

crisscross pattern to the 75% torque value.

6. Repeat Step 5, tightening the Cap Screws to the full torque value as shown in the table below.

7. Recheck the torque on all Cap Screws. If the torque is less than the minimum shown, tighten them

to the full torque.

Valve Size

intermediate

Final

10%

75%

Min.

Max.

4

14

104

127

150

6

22

167

205

240

8

34

257

315

370

10

22

167

205

340

12

34

257

315

370

14

34

257

315

370

16

54

407

500

585

18

70

521

640

750

20

70

521

640

750