Mccanna/marpac valves – Flowserve E-Series Two-Piece User Manual

Page 3

Advertising
background image

MMAIM2004

E-Series Two-Piece, Flanged-End Ball Valves

3

Table 1

Torque

Wrench Size

Requirement

Valve

(Across Flats)

(Ft.-Lbs.)

6" Class

1

1

/

4

"

263

150 ERP1

6" Class

1

7

/

16

"

424

300 ERP3

8" Class

1

1

/

16

"

148

150 ERP1

8" Class

1

1

/

4

"

263

300 ERP3

10" Class

1

7

/

16

"

424

150 ERP1

10" Class

1

1

/

4

"

263

300 ERP3

12" Class

1

7

/

16

"

424

150 ERP1

Table 3

Stem Nut

Torques

(lb-ft)

Number of Seals

SIZE

TORQUE

UPPER

LOWER

2"

10

1

2

3" & 4"

15

3

3

6"

20

3

3

8"

20*

3

3

10"

25*

3

3

12"

25*

3

3

* Graphite stem seals should be compressed to 85% of their original height. Torques
should be applied after the seals have been compressed.

Table 2

Torque

Wrench Size

Requirement

Valve

(Across Flats)

(Ft.-Lbs.)

2" Class

5

/

8

"

32

150 EFP1

2" Class

7

/

8

"

74

300 EFP3

3" Class

15

/

16

"

107

150 EFP1

3" Class

1

1

/

16

"

148

300 EFP3

4" Class

1

1

/

16

"

148

150 EFP1

4" Class

1

1

/

16

"

148

300 EFP3

6" Class

1

1

/

16

"

148

150 EFP1

6" Class

1

1

/

4

"

263

300 EFP3

8" Class

1

1

/

4

"

263

150 EFP1

8" Class

1

7

/

16

"

424

300 EFP3

10" Class

1

1

/

4

"

263

150 EFP1

10" Class

1

5

/

8

"

636

300 EFP3

12" Class

1

1

/

4

"

263

150 EFP1

12" Class

1

1

/

8

"

195

300 EFP3

Flow Control Division

McCANNA/MARPAC Valves

Advertising