UNPACKING

2.1

Each delivery includes a packing slip. When unpack-
ing, check all delivered valves and accessories using
this packing slip.

2.2

Larger valves can be lifted using slings on the yoke
rods or, if present, on the lugs provided for this pur-
pose. If slings are used, attach them so that the outer
tubing or attaching parts are not damaged.

WARNING:

If slings are used, be aware that the centre

of gravity of the valve may be above the lifting point.
In this case, secure or support the valve against rotat-
ing, to prevent damage or personnel injury.

2.3

Report transport damage to the carrier immediately.

2.4

In case of discrepancies, contact your nearest
FLOWSERVE sales office.

3

INSTALLATION

3.1

Clean tubing prior to installing.

3.2

If possible, install the valve in an upright position (ac-
tuator on top), to ease maintenance. An upright in-
stallation position is important with low-temperature
applications, in order to keep the distance between
the packing material and the medium as large as pos-
sible. The packing material then retains the ambient
temperature as much as possible.

NOTE:

Do not insulate extension bonnets that are pro-

vided for hot or cold services

3.3

Make sure that sufficient overhead clearance above
the actuator is maintained, to allow for disassembly
of plug from the valve body (see following table).

3.4

After installing, check direction of flow again. The di-
rection of flow is shown by the arrow on the housing.

3.5

If the valve is to be welded into the line, make sure
that the valve is shielded from excessive heat.

3.6

Connect supply pressure and signal lines. Control
valves are supplied with a positioner. The end con-
nections for supply pressure and signal are clearly
marked. Actuator and positioner are suitable for max.
4.2 bar (60 psi) supply pressure. If the supply pres-

Actuator

Clearance

Actuator

Clearance

size

(mm)

size

(mm)

37/47

95

P2

140

38/48

140

P3

140

39/49

140

P4

140

39D/49D

140

P5

140

1.6

Spare parts

Use only Kämmer original spare parts. Kämmer
cannot accept responsibility for any damages that
occur from using spare parts or fastening materials
from other manufactures. If Kämmer products
(especially sealing materials) have been on store for
longer periods check these for corrosion or deterior-
ation before using these products. Fire protection for
Kämmer products must be provided by the end user.

1.7

Service / repair

To avoid possible injury to personnel or damage to
products, safety terms must be strictly adhered to.
Modifying this product, substituting nonfactory parts,
or using maintenance procedures other than outlined
in this instruction could drastically affect performance
and be hazardous to personnel and equipment, and
may void existing warranties. Between actuator and
valve there are moving parts. To avoid injury
Flowserve provides pinch-point-protection in the form
of cover plates, especially where side-mounted
positioners are fitted. If these plates are removed for
inspection, service or repair special attention is
required. After completing work the cover plates must
be refitted.

Apart from the operating instructions and the
obligatory accident prevention directives valid in the
country of use, all recognised regulations for safety
and good engineering practices must be followed.

WARNING:

Before products are returned to Kämmer

for repair or service Kämmer must be provided with
a certificate which confirms that the product has been
decontaminated and is clean. Kämmer will not accept
deliveries if a certificate has not been provided (a form
can be obtained from Kämmer).

1.8

Storage

In most cases Kämmer Products are manufactured
from stainless steel. Products not manufactured from
stainless steel are provided with an epoxy resin
coating. This means that Kämmer products are well
protected from corrosion. Nevertheless Kämmer
products must be stored adequately in a clean, dry
environment. Plastic caps are fitted to protect the
flange faces to prevent the ingress of foreign
materials. These caps should not be removed until
the valve is actually mounted into the system.

1.9

Valve and actuator variations

These instructions cannot claim to cover all details
of all possible product variations, nor in particular
can they provide information for every possible
example of installation, operation or maintenance.
This means that the instructions normally include only
the directions to be followed by qualified personal
where the product is being used for is defined
purpose. If there are any uncertainties in this respect
particularly in the event of missing product-related
information, clarification must be obtained via the
appropriate FLOWSERVE sales office.

STOP!

STOP!

Advertising
This manual is related to the following products: