Trouble-shooting Chart

Fault

Possible Cause

Remedy

Stem motion

1. Packing excessively tightened

1. Tighten gland nut slightly more than „finger-tight“

impeded

2. Operating temperature too

2. Note operating data and contact dealer

high for selected trim
3. Supply pressure inadiquate

3. Check system for leaks in the supply pressure or signal lines. Re-
tighten the connections, if necessary replace leaky lines

4. Positioner defective

4. See operating instructions for positioner

Excessive

1. Bonnet loose

1. See step 7.2.6 for correct tightening of bonnet.

leakage

2. Worn or damaged

2. Re-machine or replace seat ring/plug.

seat ring/plug
3. Gaskets damaged

3. Replace gaskets

4. Inadiquate actuator thrust

4. Check air feed. If air feed is OK, contact dealer.

5. Plug incorrectly adjusted

5. Correctly adjust plug according to step 6.2.4

6. Incorrect direction of flow

6. Check specification. Contact dealer

7. Handwheel incorrectly

7. Adjust handwheel

adjusted (acts like end stop)

Inadiquate flow

1. Plug incorrectly adjusted

1. Correctly adjust plug according to step 6.2.4

(short stroke)
2. Positioner defective

2. See operating instructions for positioner

3. Operating requirements

3. Check operating data. Contact dealer

too high

Plug slams

1. Plug adjustment incorrect

1. Correctly adjust plug according to step 6.2.4

2. Inadiquate supply pressure

2. Check supply pressure, seal leaks, remove blockage

3. Trim too large for

3. Replace trim

flow rate

Regional Headquarters

Flowserve

Flowserve

Flowserve

Manderscheidtstr. 19

1350 N. Mt. Springs Prkwy.

12 Tuas Avenue 20

45141 Essen

Springville, UT 84663

Germany

USA

Singapore 638824

Telephone: +49 (0) 201 8919 5

Telephone: +1 801 489 8611

Telephone: +65 862 3332

Facsimile: +49 (0) 201 8919 662

Facsimile: +1 801 489 3719

Facsimile: +65 862 4940

Main Sales Offices (Europa, Middle east, Africa)

Flowserve

Flowserve

Flowserve

Flowserve

von-Braun-Straße 19a

12, av. du Québec

Station Road

Allee du Quartz 1

48681 Ahaus

91965, Courtaboeuf Cedex

Pershore, Worcestershire

CH-2300 La-Chaux-de Fonds

Germany

France

England WR102BZ

Switzerland

Telephone: +49 (0) 2561 6860

Telephone: +33 (0) 1 60 923 251

Telephone: +44 (0) 1386 55 45 51

Telephone: +41 (0) 32 925 9700

Facsimile: +49 (0) 2561 68648

Facsimile: +33 (0) 1 60 923 299

Facsimile: +44 (0) 1386 55 49 68

Facsimile: +41 (0) 32 926 5422

Flowserve

Flowserve

Cnr. Bismit and Granier Str.

C/O Saleh & Abdulaziz Abahsain

Jet Park Ext 3

P.O. Box 209

Boksburg
1459 Gauteng

Al Khobar 31952

South Africa

Saudi Arabia

Telephone: +27 397-3150

Telephone: 9663 857 3442

Facsimile: +27 397-5300/01/02

Facsimile: 9663 859 5284

All data subject to change without notice

©09.2003 Flowserve Corporation. Flowserve and Kämmer are trademarks of Flowserve Corporation

Advertising
This manual is related to the following products: