Flow Control Division

Kammer Control Valves

Fault

Possible Cause

Remedy

Stem motion

1. Packing excessively tightened

1. Tighten gland nut (see table 1)

impeded

2. Operating temperature too

2. Note operating data and contact dealer

high for selected trim
3. Supply pressure inadiquate

3. Check system for leaks in the supply pressure or signal lines. Re-

tighten the connections, if necessary replace leaky lines

4. Positioner defective

4. See operating instructions for positioner

Excessive

1. Bonnet loose

1. See step 21.7 for correct tightening of bonnet.

leakage

2. Worn or damaged

2. Re-machine or replace seat ring/plug.

seat ring/plug
3. Gaskets damaged

3. Replace gaskets

4. Inadiquate actuator thrust

4. Check air feed. If air feed is OK, contact dealer.

5. Plug incorrectly adjusted

5. Correctly adjust plug according to step 18.3

6. Incorrect direction of flow

6. Check specification. Contact dealer

7. Handwheel incorrectly

7. Adjust handwheel

adjusted (acts like end stop)

Inadiquate flow

1. Plug incorrectly adjusted

1. Correctly adjust plug according to step 18.3

(short stroke)
2. Positioner defective

2. See operating instructions for positioner

3. Operating requirements

3. Check operating data. Contact dealer

too high

Plug slams

1. Plug adjustment incorrect

1. Correctly adjust plug according to step 18.3

2. Inadiquate supply pressure

2. Check supply pressure, seal leaks, remove blockage

3. Trim too large for

3. Replace trim

flow rate

22 Trouble-shooting chart

All data subject to change without notice

©09.2003 Flowserve Corporation. Flowserve and Kämmer are trademarks of Flowserve Corporation

Regional Headquarters

Flowserve EMA

Flowserve America

Flowserve Asia

Burrell Road, Hayward Heath

1350 N. Mt. Springs Prkwy.

12 Tuas Avenue 20

West Sussex, RH16 1TL

Springville, UT 84663

638824

England

USA

Republic of Singapore

Telephone: +44 (0) 1444 314400

Telephone: +1 801 489 8611

Telephone: +65 862 3332

Facsimile: +44 (0) 144 3144401

Facsimile: +1 801 489 3719

Facsimile: +65 862 4940

Main Sales Offices EMA (Europe, Middle East, Africa)

Flowserve France

Flowserve UK

Flowserve Switzerland

Flowserve Germany

7 Avenue de la Libération

Station Road

Allee du Quartz 1

Manderscheidtstr. 19

63300 Thiers Cedex

Pershore, Worcestershire

CH-2300 La-Chaux-de Fonds

45141 Essen

France

England WR102BZ

Switzerland

Germany

Telephone: +33 (0) 4 73 80 42 66

Telephone: +44 (0) 1386 55 45 51

Telephone: +41 (0) 32 925 9700

Telephone: +49 (0) 201 8919 5

Facsimile: +33 (0) 4 73 80 14 24

Facsimile: +44 (0) 1386 55 49 68

Facsimile: +41 (0) 32 926 5422

Facsimile: +49 (0) 201 8919 662

Flowserve South Africa

Flowserve Middle-East

Flowserve Austria

Flowserve Benelux

Units 1 and 2

C/O Saleh & Abdulaziz Abahsain

Kasernengasse 6

Van Leeuwenhoekweg 6

26, Imvuba Road, Sebenza Ext 6

P.O. Box 209

Edenvale, Gauteng
Edenglen 1613

Al Khobar 31952

9500 Villach

3225 LX Hellevoetsluis

South Africa

Saudi Arabia

Austria

The Netherlands

Telephone: +27 11 609 2094

Telephone: 9663 857 3442

Telephone: +43 (0) 424241 181-0

Telephone: +31 (0) 181 330044

Facsimile: +27 11 609 3735

Facsimile: 9663 859 5284

Facsimile: +43 (0) 424241 181 50/51

Facsimile: +31 (0) 181 330040

Flowserve Italy

Flowserve Spain

Flowserve Portugal

Flowserve Scandinavia

Via Prealpi, 30

Luis Cabrera, 86-88

Av. Dr. Antunes Guimaraes, 1159

Gelbgjutaregatan

Cormano (Milano)

E-28002 Madrid

Porto 4100-082

58933 Linköping, Östergötland

Italy

Spain

Portugal

Sweden

Telephone: +39 (0) 2663251

Telephone: +34 9 15 152 032

Telephone: +351 22 619 8770

Telephone: +46 13 316100

Facsimile: +39 (0) 26151863

Facsimile: +34 9 14 136 747

Facsimile: +351 22 619 7575

Facsimile: +46 13 136054

Flowserve Eastern Europe
12, av. du Québec
91965, Courtaboeuf Cedex
France
Telephone: +33 (0) 1 60 923 251
Facsimile: +33 (0) 1 60 923 299

Advertising