Flowserve OR 52-5 User Manual

Page 10

Advertising
background image

10

Explanatary Notes

continued

Technical Data

1)

At a flowrate of 2 l/min and V-shaped flow through the sensor with a pipe length of 1 m
(DN 10) and 4 bends,

ζ=6.1.

2)

A pH value above 10.5 can lead to wear of the glass, depending on the temperature.

3)

Vent nipple screwed in measuring transducer as standard.

Measuring sensor ORG 12, ORG 22

Nominal pressure PN

10 bar g (145 psi g)

Nominal size DN

10, screwed “ ¤§8 BSP to DIN ISO 228

Flowrate 0.5–50

l/min

Pressure drop

1)

5 mbar

Corrosive resistance

Water, condensate, beverages, etc.

Max. pH value of fluids

2)

10.5

Fluid temperature range

0–60 °C

(with drying cartridge)

60–120 °C

(with vent nipple)

Approx. weight

6.8 kg

Materials

ORG 12

ORG 22

Housing

0.6025 galvanized

0.6025 galvanized

Cover

0.6025 galvanized

1.4580

Wetted parts

0.6025 galvanized

1.4580

Ball valves

Brass 58

1.4436

Screwed unions

Steel

1.4571

Glass cylinder

Duran 50

Duran 50

Gaskets

Silicone

Silicone

Cleaning disc

EPDM

EPDM

Light emitter

Glow lamp 12V/10W BA 15s

Protection IP 65

Light receiver

2 silicon-type photo-electric cells

Protection IP 65

F

Advertising
This manual is related to the following products: