Flowserve Valtek MaxFlo 3 User Manual

Page 7

Advertising
background image

®

User instructions - MaxFlo 3 - VLENIM0052-02 02.07

7

7.0 Place the bonnet gasket (item 58) on the gasket step in-

side the body. Gently push the bonnet into the bonnet

bore.

NOTE: When installing the bonnet, orient the milled faces

on the bonnet perpendicular to the flanges of the valve

body.

7. Place the packing stop (item 99) into the bonnet, then in-

stall the packing spacer (item 93) and packing as shown

in figure 3.

7. Install bonnet nuts and tighten to finger tight.

7.3 Install the packing follower (item 87) and gland flange

(item 80), then tighten the packing nuts to finger tight.

7.4 Tighten the bonnet and end post nuts evenly. Torque

nuts to the values listed in table II.

7.5 Install the shims (item 3) and seat ring (item 0) as

described in the Seat Replacement section.

7.6 Install the actuator and yoke as described in the installa-

tion manual for the corresponding actuator.

7.7 Install the valve into the process line as described in the

installation section.

Figure 3: Packing Configurations

Standard V-ring

Twin V-ring

Twin V-ring Vacuum Seal

Standard graphite

Twin graphite

“Live Loading” system:
- optional for SureGuard / XT
- standard for SafeGuard

“Live Loading” system:
- optional for SureGuard / XT
- standard for SafeGuard

Standard SureGuard

Standard SureGuard XT

Twin SureGuard

Twin SureGuard XT

Standard SureGuard Firesafe

Standard SureGuard XT Firesafe

Twin SureGuard Firesafe

Twin SureGuard XT Firesafe

Advertising
This manual is related to the following products: