Flowserve ZK210 User Manual

Page 11

Advertising
background image

11

Explanatory Notes

(continued)

Capacity Charts

Cold water

Hot water t

s

–5 K

The charts show the maximum flowrates of cold and hot water at the extreme regulation
position with linear characteristic curves and maximum K

vs

value.

K

vs

Values and Actuator Selection Data

Important

In the installation instructions, standard values are described. For possible
deviations, please see the name plate of the control valve.

DN Nozzle

*)

Characteristic K

vs

value

[m3/h]

Valve
lift

[mm]

Revol.
for full
valve
lift

Max. admiss.
torque for
opening/
closing

[Nm].

Type/size of
actuator
DIN ISO
5210

25

3-stage linear

0.8 1.5 2.3

18

3.6

20 / 20

F10 - B1

25

3-stage equal %

0.8 1.5 2.3

18

3.6

20 / 20

F10 - B1

25

4-stage linear

0.5

13

2.6

20 / 20

F10 - B1

50

3-stage linear

3.3 6.5 10

35

7

30 / 60

F10 - B1

50

3-stage equal %

3

6

9

35

7

30 / 60

F10 - B1

50

5-stage linear

2

23

4.6

30 / 60

F10 - B1

80

3-stage linear

9.5 18

28

50

10

80 / 120

F10 - B1

80

3-stage equal %

8.5 18

25

50

10

80 / 120

F10 - B1

80

5-stage linear

5

35

7

80 / 120

F10 - B1

*) 3-stage:

∆p

max

= 100 bar (standard), 4/5-stage:

∆p

max

= 180 bar

Advertising
This manual is related to the following products: