Operating procedure – Flowserve ZK210 User Manual

Page 15

Advertising
background image

15

Operating Procedure

(continued)

Maintenance

(continued)

The following maintenance work must be performed:

Type of
maintenance

Time interval Activities

Inspection

Quarter-yearly Checking the stuffing box for leaks

1

) (visual inspection)

Inspection

Quarter-yearly Checking that connections, body seal, valve spindle and

threaded spindle are free of wear, are clean, and are not
leaking (visual inspection)

Inspection

Quarter-yearly Checking of seat tightness

Inspection

Annually

Checking that the fastening screws of the valve actuator are
seated securely, and tightening them if necessary

Lubrication

Quarter-yearly Lubricating the spindle bearing with lithium-saponified

grease with penetration grade 2 with MoS

2

additive

2

)

Inspection

Every three
years

Checking by Gestra specialists to ensure that the internal
parts and threaded spindle are not damaged

1

) Replenishment or exchange of the stuffing box rings may only be performed when there is

no pressure in the valve. In particular, the safety information and danger notes in the
section entitled "Important Notes" must be observed.

Important

The task of opening the body may only be performed by specialists from
Gestra.

2

) Lubricants recommended by the manufacturer are:

„

Shell Retinax AM with MoS

2

„

DEA Glissando MEP2

Advertising