Troubleshooting, Accessories – Desa 000 User Manual

Page 7

Advertising
background image

111695-01A

7

7

For more information, visit www.desatech.com

For more information, visit www.desatech.com

SYMPTOM

Burner fails to light

Burner lights but goes out when automatic
control valve button is released

Burn rate is low

POSSIBLE CAUSE

1. Propane supply valve closed on propane

tank(s)

2. Excess flow check valve closed

3. Blockage in burner orifice
4. Piezo ignition system not sparking

1. Not enough warm up time

2. Low gas pressure

3. Thermocouple loose or needs to be

replaced

4. Automatic control valve needs to be

replaced

1. Control valve is on LOW

2. Plugged gas orifice
3. Low gas pressure

4. Low fuel supply

REMEDY

1. Open propane supply valve slowly

2. Close propane supply valve on propane

tank and reopen slowly

3. Replace burner orifice
4. Check to assure ignitor electrode gap is

.195" Check wire lead for damage. Re-
place piezo ignitor and/or ignitor elec-
trode as necessary

1. Relight, hold automatic control valve

button in 45 seconds

2. Check propane tank(s) for proper gas

supply

3. Tighten connection or replace ther-

mocouple

4. Replace automatic control valve

1. Push and turn valve counter clockwise

to MED or HIGH

2. Replace gas orifice
3. Check gas supply; check regulator

output

4. Consult propane gas supplier

TROUBLESHOOTING

WARNING: Never attempt to service heater while it is connected

to propane supply, operating, or hot. Severe burns can occur.

Note:

For additional help, visit DESA Heat-

ing Products’ technical service website at

www.desatech.com.

ACCESSORIES

Purchase these heater accessories and parts from your nearest dealer or
service center. If they can not supply an accessory or part, either contact
your nearest Parts Central (listed in the separate Authorized Service
Center booklet) or call DESA Heating Products’ at 1-866-672-6040.
You can also write to the address listed on the back page of this manual.

Part Number

Description

LPA4020

Fuel Gas Connector

Connects regulator to all standard propane
tanks. U.L. and AGA listed.

LPA1000

10 Foot Hose

LPA2160

Regulator

LPA3110

Hose and Regulator Assembly

TROUBLESHOOTING

ACCESSORIES

Advertising
This manual is related to the following products: