Automax XCL/XML Switch Box User Instructions FCD AXENIM0120-13-A4 02/15

10

Part

Materials

Housing/Cover

Aluminum w/ Dichromate & Polyester Powdercoat

Shaft

Stainless Steel

Cams/Splines

Nylon

UltraDome and Rotor

Polycarbonate

Terminal Block

Nylon – Buchanan TBS Series

Internal Brackets

Stainless Steel or Plated Steel

All Internal Fasteners

Stainless Steel or Plated Steel

All External Fasteners

Stainless Steel

UltraDome

Lexan or Ektar™

Rotor

Polycarbonate

a

CAUTION: If the equipment is likely to come into contact with corrosive substances, then it is the responsibility of the user to ensure that the

type of protection provided by the equipment is not compromised.

7 Materials

8 Dimensions

8.1 Max Safe Gaps

The maximum constructional gap is less than that required by Table 1 of IEC/EN 60079-1:2003/2004 as detailed below.

Flamepath

Maximum Gap (mm)

Comment

Cover and base

0.058 (0,038 for CSA)

Flanged joint

Operating rod and cover bushing

0.088

Cylinderical spigot joint

Cover and bushing

0.00

Interference fit

Operating rod and base bushing

0.088

Cylinderical spigot joint

Base and bushing

0.00

Interference fit