If you wish to make a direct electrical connection to the blower without using the six-foot

cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location.
Remove the power cord and connect the 120V line as per the following procedure :

• Unscrew the speed control unit and pull a few inches away from the junction box
• Unscrew the two marr connectors attached to the cord (P) and the cord ground
• Remove the cord and route the supply line through the same holes
• Make the electrical connection with the same wires the cord was attached to
• Screw the ground wire to the junction box (G)
• Screw the speed control unit back in place

P

P

G

CONNECT THE POWER LINE TO THE SAME

WIRES THE CORD WAS CONNECTED TO (P)

SPEED CONTROL

JUNCTION BOX


If you prefer to use the six-foot cord supplied, just connect it to a 120V outlet.

• Move the ELATION to the desired position and shim the unit to a level position.

• Connect gas line to the insert at the right side using listed connectors

• Check the gas line piping for leaks. Use a soap and water solution.


WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS.