4. CERTIFICATES

ATEX II 2 GD Ex d IIC T4 Gb, Ex tb IIIC T113°C Db IP66

IECEx Ex d IIC T4 Gb, Ex tb IIIC T113°C Db IP66

5. SPECIFICATIONS

5.1 Technical data

Enclosure ratings

IP66, IEC 529

Weight Aluminum housing

1.8kg / 4 lbs

Weight Stainless Steel housing

3.5kg / 7.75 lbs

Working Temperature:

-40°C to +85°C / -40°F to +185°F

Maximum Surface Temperature:

+120°C / +248°F

5.2 Materials of construction

Housings & Covers

Powder epoxy painted Aluminum or Stainless Steel

Shaft

Stainless

Steel

Cams/Splines

Nylon

Terminal

Block

Nylon

Internal Brackets

Nylon, Aluminum or Stainless Steel

All External Fasteners

Stainless Steel

All Internal Fasteners

Stainless Steel

Indicator

Polycarbonate/Polyurethane

Label

Polyester or Stainless Steel

Product name and model code

Warnings

Year of
manufacture

Manufacturer

Electrical
rating

Serial number

Logotype

5.3 Product label

All certificates available for

download at www.pmv.nu

FCD PMENIM0020-00 - 02/15

FCD PMENIM0020-00 - 02/15

A =

Product & Connections (cable entry)

DS

Explosion proof / Flame proof switch box with 3/4” NPT cable entries

DM

Explosion proof / Flame proof switch box with M25x1,5 cable entries

B =

Number of open cable entries

2

2 x open cable entries (standard)

3

3 x open cable entries (option)

C =

Housing material /Surface treatment

B

Aluminum housing, polyester powdercoating, Black base & cover

W

Aluminum housing, polyester powdercoating, Black base & White cover

C

Aluminum housing, polyester powdercoating, Black base & Optional cover color

S

Stainless Steel housing DIN 1.4408 - EN G-X 6 CrNiMo 18-10 - SAE 316

D =

Shaft

D

Double ’D’ Shaft 1/4”

N

Namur VDI/VDE 3845 Shaft (rotary actuators)

T

For NAF Turnex actuators

L

D style including nut for linear applications

E =

Indicator option

0

Flat top cover, no indicator

1

Flat top cover, indicator below switchbox for 90 deg

F =

Qty of switches

0

0 switches (Cam assembly for 2 x M1 only)

2

2 Switches

4

4 Switches

G =

Switch options - see page 6 for switch options

H =

Certificate

14

General Purpose

19

ATEX II 2 GD Ex d IIC, IECEx Ex d IIC

I =

Product approval marking

0

Self-adhesive marking label, Polyester

M

Stainless steel marking plate

J =

Analog Output

0 None

4

4-20mA transmitter

(F=0 only)

K =

Terminal Options

2

2 Extra open terminals (Standard)

4

4 Extra open terminals (Optional, not possible for all switch options)

6

6 Extra open terminals (Optional, not possible for all switch options)

8

8 Extra open terminals (Optional, not possible for all switch options)

H

Heavy Duty Terminal Block, 8 contact points.

L =

Options/ Elastomers

0

Nitrile O-rings

V

Viton O-rings

M =

Brand

P PMV

Ordering code example

A

B C D E F

G

H

I

J K L M

DS 2 B N 1 2 MG - 14 - 0 0 2 0 P