Model DP569 User’s Manual

Error Messages

D–2

NOT VALID:

CHECK

INPUT FORMAT

• Ref In-SRC On or an Internal Clock Source has been selected and the

current Input Format is not PCM.

• Time Code Ctrl has been selected as the Encoder State and the current

Input Format is not PCM.

NOT VALID:

CHECK

ENCODER STATE

• Time Code-based Recall has been selected and Encoder State is currently

set to Time Code Ctrl.

• Pre-encoded or Autodetect has been selected as the Input Format and the

current Encoder State is set to Time Code Ctrl.

• Multiplex Mode has been set to Enabled and the current Encoder State is

set to Time Code Ctrl.

NOT VALID:

CHECK

MULTIPLEX MODE

• Digital Input or an Internal Clock Source has been selected, and Multiplex

Mode is currently Enabled.

• Pro 32-bit or Consumer has been selected as the Output Mode and

Multiplex Mode is currently Enabled.

• Time Code Ctrl has been selected as the Encoder State and Multiplex

Mode is set to Enabled.

NOT VALID:

CHECK

CLOCK SOURCE

• Pre-encoded or Autodetect has been selected as the Input Format and the

current Clock Source is Ref In-SRC On or an Internal clock source.

• The Multiplex Mode has been Enabled and the current Clock Source is

Digital Input or Internal.

• A Coding Delay value less than 204 ms has been selected and the current

Clock Source is Internal 44.1 kHz, or a Coding Delay less than 280 ms has
been selected and the current Clock Source is Internal 32 kHz.

Advertising