How to order – Flowserve DC Motor Controller Board User Manual

Page 4

Advertising
background image

LME0005-1 (AUTO-43) 07/03
©

2003, Flowserve Corporation, Printed in USA

3-Position Control/Dribble Control

SR Limit Switch Method

Flowserve Corporation

1350 N. Mountain Springs Parkway

1978 Foreman Dr.

Flow Control Division

Springville, Utah 84663-3004

Cookeville, TN 38501

www.flowserve.com

Phone: 801 489 8611

Phone: 931 432 4021

Automax Valve Automation Systems

Installation, Operation and Maintenance Instructions

Page 4 of 4

CENTURA Series Actuator - CE

Extras

Size

Motor

Switches

Options

Conduit

(can add more than one)

250 in-lbs -2

12 VDC (without brake) -B

One extra -1

DC Motor Controller -DA

Right Hand -Blank

Epoxy Coating -E

400 in-lbs -4

24 VDC (without brake) -C

Two extra -2

4-20mA Transmitter -TX

Both Left & Right -X

Heater & Stat -H

700 in-lbs -7

Three extra -3

0-135 Ohm Potentiometer -P1

Manual Handwheel -Z

1,000 in-lbs -1

Four extra -4

0-1000 Ohm Potentiometer-P2

1,500 in-lbs -5

0-5000 Ohm Potentiometer-P3

0-10K Ohm Potentiometer -P4

0-1000, 0-10K Dual Pot -P6

Troubleshooting Guide
1.

No LED indicators lit:
A.

DC Power Supply not on

B.

On-board fuse blown, check for proper
power polarity and voltage level at
+++/POWER and GND (TB1 pins 7 and
8), replace fuse.

C.

LED switch set to OFF

2.

Actuator is not responding to remote inputs:
A.

Ensure on-board local control switches
LOCAL/REMOTE are set to REMOTE.

B.

Check polarity of signaling terminal
wiring, and proper voltage measurements,
see Page 3, Input Configurations.

C.

Check LED F (fault) latch set, adjust
I SENSE adjustment as required,
following instructions on Page 2.

D.

Check that jumpers J3 & J4 are both on
left two posts or both on right two posts
as desired. See diagram on Page 3 for directions.

DC Motor Actuator Specifications

DC Motor System

12V

24V

Supply Voltage (maximum)

14V

28V

Volts

Remote Signal (18AWG)

5000

5000

ft.

Cycle Time*, (min/max adj)

CE2B, CE2C

6-14

6-14

sec.

CE4B, CE4C

8-20

8-20

sec.

CE7B, CE7C

15-31 15-31

sec.

CE1B, CE1C

20-42 20-40

sec.

CE5B, CE5C

32-60 30-60

sec.

Supply Currents (typ.)

Controller Board

10**

15**

mA

DC Motor (full load)

1.60

0.9

A

I Sense Adj. (max)

2.0

2.0

A

Operating Temperature

-40 to 160 Deg. F
(-40 to 70 Deg. C)

* - Times are approximate under no load conditions and
may vary slightly under actual operating conditions.

** - Board options set at minimum current draw.

How to Order

(Select from each column)

Weight CE2, CE4, CE7, CE1 = approx. 18 lbs., CE5 = approx. 20 lbs.
Ordering Example: Automax CENTURA Series Electric Rotary Actuator capable of 400 in-lbs. torque, to operate on 12 VDC with DC Motor
Controller would read: CE4BDA
*Flowserve can supply special mounting on the bottom of the CENTURA Series actuators to direct couple to many common valve lines.
**No mechanical solenoid brake as supplied on AC Actuators.

**