12






FEATURE DESCRIPTIONS (CON.

)

Sequential Start-up

Sequential start-up (Figure 40) is implemented by placing
an On/Off control circuit between Vo

PS1

and the On/Off pin

of PS2.









Simultaneous

Simultaneous tracking (Figure 41) is implemented by
using the TRACK pin. The objective is to minimize the
voltage difference between the power supply outputs
during power up and down.

The simultaneous tracking can be accomplished by
connecting Vo

PS1

to the TRACK pin of PS2. Please note

the voltage apply to TRACK pin needs to always higher
than the Vo

PS2

set point voltage.





R1

R2

Vo

PS1

PS1

Vin

On/Off

On/Off

PS2

Vo

PS2

Vin

C1

Q1

R3

TRACK

Vo

PS1

PS2

Vo

PS2

PS1

Vin

Vin

On/Off

On/Off