Installation – Flowserve UNA 14 User Manual

Page 13

Advertising
background image

13

Name plate / Marking

Ratings and design as specified in EN 19 and EN ISO 26652 on name plate which is firmly attached
to the trap body/cover.

Type designation

UNA 1 ...h:

horizontal design

UNA 1 ...v:

vertical design

SIMPLEX or DUPLEX:

type of control unit (see “Description”)

additional “P”:

with Perbunan

®

valve ball (max. 40 °C)

additional “R”:

provided with internal venting pipe

O...(orifice):

installed orifice

Stamp on name plate, e. g. indicates term and year of production
(Example: 4

th

quarter 2003)

Corrosion resistance

If the unit is used for the intended purpose, its safety is not impaired by corrosion.

Sizing

The trap body must not be subjected to sharp increases in pressure.
The dimensional allowances for corrosion reflect the latest state of technology.

UNA 14, UNA 16, UNA 16 A, UNA 14 P

Installation

Float-operated steam traps can – depending on the design of the trap body – be installed in
horizontal or vertical lines with downward flow. Conversion to obtain a different flow direction
is possible:

Flanged design

1. Observe position of installation. The name plate E must always be on top.

2. Observe the direction of flow. The arrow indicating the flow direction A is on the trap body.

Change direction of flow of UNA 14, UNA 16, UNA 16 A or UNA 14 P if necessary.

3. Consider space required for opening trap. When the trap is installed a minimum space of at least

120 mm is required for removing the cover I!

4. Remove plastic plugs. They are only used as transit protection.

5. Clean seating surfaces of both flange faces.

6. Install trap.

Perbunan

®

is a registered trademark of Bayer AG, Leverkusen

Design
Control unit

TMA

PN / Class

DN

Name plate
must be on top

Orifice

4

03

Design
Control unit

TMA

PN / Class

Name plate
must be on top

DN

Orifice