Maintenance – Flowserve UNA 14 User Manual

Page 18

Advertising
background image

18

Item

Steam trap

UNA 14, UNA 16, UNA 16 A, UNA 14 P

UNA 14, UNA 16, UNA 14 P

75

35

Torque [Nm]

UNA 16 A

35

All torques indicated in the table are based at a room temperature of 20 °C.

WINIX

®

2150 is a registered trademark of WINIX GmbH, Norderstedt

Tools

Hexagon-type offset screwdriver (size 8), DIN 911L

Screwdriver (5.5/125), DIN 5265

Punch (120/10), DIN 7250

Hammer (500 g), DIN 1041

Torques

Maintenance

– continued –

Clean / replace thermostatic capsule (only DUPLEX design)

1. Remove cover I from body B, fig. 3
2. Lever control unit N off its support using a screwdriver, fig. 4
3. Remove old cover gasket O.
4. Clean seating surfaces of body and cover. Insert new gasket O.
5. Remove retainer C from control unit N and take out thermostatic capsule D.
6. Insert new or cleaned thermostatic capsule and push retainer C over the thermostatic

capsule. fig. 3

7. Clean seating surfaces of body and cover. Insert new gasket O.
8. Position control unit N on support and fix it by sharp blows, fig. 5
9. Apply heat-resistant lubricant to seating surfaces of cover and threads of fixing screws (use for

instance WINIX

®

2150).

10. Insert a new gasket and put cover onto trap body. Tighten body screws in diagonally opposite

pairs to a torque of 35 Nm. Retighten screws after the commissioning procedure.

F G J

P

P

Advertising
This manual is related to the following products: